Please fill out the form below:








    Contact Us

    How to Set Up a New Laboratory: Equipment Checklist for Australian Facilities

    How to Set Up a New Laboratory: Equipment Checklist for Australian Facilities

    Setting up a new lab is a bigger job than most facility managers expect, and a solid lab equipment list is only useful if it’s built on the right planning, infrastructure and compliance foundations. Skip a step in that sequence, and it shows up later as a costly one, whether that’s equipment that doesn’t fit the bench or gear that fails audit on day one.

    Let’s explore how to set up a laboratory in Australia step by step, from planning to commissioning, with a practical checklist you can hand straight to your procurement team.

    Key Insights

    • Nail down purpose, budget and compliance requirements before you spec a single instrument.
    • Confirm power, water, ventilation and bench layout before ordering equipment.
    • Build your laboratory equipment list by function (temperature control, sterilisation, safety, analysis).
    • Budget for calibration, commissioning and NATA accreditation, not just purchase price.
    • Involve your equipment supplier early and keep in mind that custom builds take longer to source than off-the-shelf units.

    Step 1: Define Purpose, Budget and Compliance Needs

    Start by writing down exactly what your lab will do (diagnostics, QA testing, R&D, teaching), because this decides everything downstream. Loop in compliance early as well. NATA accreditation, TGA requirements or state health department approval can all dictate equipment tolerances before you buy anything.

    Realistic budget bands (equipment and fit-out, excluding building works):

    • Teaching lab: roughly $50,000–$150,000
    • Research lab: roughly $200,000–$800,000+
    • Commercial testing lab: $500,000 and up, depending on accreditation scope

    Lab construction itself typically costs three to five times more per square metre than a standard office fit-out, largely due to services, environmental control and the difference in functionality. Budget accordingly before you get attached to a floor plan.

    Step 2: Get the Infrastructure Right First

    Equipment only performs if the building can support it. Before setting up a lab, confirm:

    • Power: Dedicated circuits for autoclaves, freezers and ovens, plus backup power for cold storage
    • Water: Mains supply for sinks and distillers, plus drainage rated for lab waste
    • Ventilation: Fume extraction sized to your fume hood count, not retrofitted afterwards
    • Benches: Chemical-resistant surfaces at the right height and depth for your equipment footprint
    • Storage: Dedicated chemical and cold storage separated from general lab space

    Step 3: Build Your Laboratory Equipment List by Category

    With infrastructure locked in, work through your lab equipment list by category rather than item; it’s easier to spot gaps this way. Our guide to essential lab equipment breaks each category down in more depth, but here’s your checklist to start with:

    Item Category Priority Notes
    Analytical balances Measurement Essential Check readability and calibration needs
    Incubators Temperature control Essential Match to cell culture or microbiology load
    Autoclave equipment Sterilisation Essential Confirm cycle type against instrument load
    Fridges and freezers Cold storage Essential Cold-chain critical, needs backup power
    Water bath Heating Recommended Gentler heating for sensitive samples
    Water distiller Cleaning/prep Recommended Sized to reagent prep volume
    Climate chamber Environmental control Recommended Needed for stability and shelf-life testing
    Laboratory freeze dryer Specialised Optional Depends on sample preservation needs. Our guide on what a laboratory freeze dryer is covers the details.
    Fume hood Safety Essential Face velocity signed off by an HVAC engineer
    Custom/purpose-built units Specialised Optional Discuss with the Labec team for customised gear

    Step 4: Lock in Safety Equipment and Compliance

    Fume hoods, eyewash stations, safety showers and PPE are specified against AS/NZS 2243. This means they aren’t optional extras when setting up a lab.

    Under Australian WHS law, businesses handling hazardous chemicals also carry duties under the model Code of Practice for managing risks of hazardous chemicals in the workplace, which covers exposure standards, chemical registers, labelling and emergency plans, so build these obligations into your plan rather than retrofitting them later.

    Step 5: Set Up IT and Data Systems

    A Laboratory Information Management System (LIMS) tracks samples, results and equipment calibration records. Even in a small facility, they are worth planning since retrofitting data systems around live workflows is disruptive. Budget for networked computers at each analytical instrument and secure backup for compliance records.

    Step 6: Commissioning and Calibration

    Every instrument on your laboratory equipment list needs commissioning and NATA-traceable calibration before it goes into service. Our guide on how to choose the right lab equipment covers calibration, maintenance and total cost of ownership in more detail.

    Common Mistakes When Setting Up a New Lab

    • Undersizing Power or HVAC: Plan your power and airflow against a confirmed lab equipment list with headroom for growth built in, so scaling up doesn’t result in a tripped circuit.
    • Forgetting Waste Disposal: Chemical and biological waste streams need a plan before day one.
    • Buying Before Measuring: Purchasing equipment before checking bench dimensions can cost you, especially when that’s across multiple units ordered on the same spec sheet.
    • Skipping Calibration Budgets: Equipment cost is only part of the total spend. NATA-traceable calibration and annual servicing add up fast once your instrument count grows.

    Build Your Lab with Confidence

    Setting up a new lab is a big undertaking, but it’s also a fresh start, and getting the sequence right from the start means less rework and more time spent on the science that matters.

    Labec has served science for over 80 years. We design and manufacture lab equipment for the Australian government, medical and pharma facilities. Our team can help match your equipment list to your space, budget and compliance requirements from the planning stage onward. Get in touch today, let’s get the groundwork right so everything after falls into place.

    FAQs

    How long does it take to set up a new laboratory in Australia?

    Depending on the scope, allow three to six months for a straightforward lab and up to 12 months or more for a facility requiring custom-built equipment and NATA accreditation.

    What’s the highest cost when setting up a lab?

    Fit-out and infrastructure (power, ventilation, plumbing) usually outweighs equipment cost, especially for facilities needing fume hoods or cold-chain storage.

    Do I need NATA accreditation before ordering equipment?

    Not necessarily before ordering, but you should confirm accreditation requirements early, since they affect calibration tolerances and equipment specification.

    Can equipment be custom-built if standard units don’t fit my space?

    Yes. Labec can design and build purpose-made units for facilities with non-standard dimensions, capacity or environmental control needs.

    What’s the difference between essential and specialised equipment?

    Essential equipment covers baseline functions every lab needs, such as measurement, temperature control, sterilisation and safety. Specialised equipment is built for specific applications, like stability testing or freeze-drying.

    Leave a Reply